EAGLE SPECIFICATIONS
EAGLE & EAGLE X LIMITED WARRANTY
The Eagle Combustion Analyzers (C75, C125, C127) are warrantied to be free from defects in materials and workmanship for a period of
thr
ee y
ears (two y
ears on sensors) fr
om the date of purchase. Eagle X (C155, C157) are each warrantied for five years including sensors.
If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEis
option.
This warranty cov
ers normal use and does not cover damage which occurs in shipment or failure which results from alteration,
tampering, accident, misuse, abuse, neglect or improper maintenance (calibration). Batteries and consequential damage resulting from failed
batteries are not cov
er
ed b
y warranty
.
Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited
to the expr
ess warranty. UEi shall not be liable for loss of use of the instr
ument or other incidental or consequential damages, expenses, or
economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase
date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service
charge. Contact UE
i for specific warranty and ser
vice information.
This warranty giv
es y
ou specific legal rights.
You may also have other
rights which vary from state to state.
USA: 1.800.547.5740 • Fax: 503.643.6322
CANADA: 1-877-475-0648 • Fax: 604.278.8299
WWW.UEiTEST.COM
COPYRIGHT © 2009 UEi. EAGLE Combustion Analyzers™ is a trademark of UEi. PRIN109/3k 10/09 18323
C125 C127 C155 C157
Temperature Measurement
Flue Temp Range 20~2400˚F (-29~1315˚C)
I
nlet Temperature (probe - T2) 20~2400˚F (-29~1315˚C)
Inlet Temperature (ambient) 32~112˚F (0~50˚C)
Net Temperature (_T)** 20~2400˚F (-29~1315˚C)
R
esolution 0.1˚C/F
Flue (T1, Inlet T2 & _T) Accuracy ±(0.3% rdg +3.6˚F(2˚C))
Inlet Temperature Accuracy ±(0.3% rdg +1.8˚F(1˚C))
Gas Measurement
Oxygen 0~21%* 0~21%* 0~21%** 0~21%**
O
2 resolution / accuracy 0.1% / ±0.2% 0.1% / ±0.2% 0.1% / ±0.3% 0.1% / ±0.3%
Carbon Monoxide (CO) 0~2000 ppm (4000 max 15 min)*
CO resolution / accuracy 1ppm/ ±10ppm<100ppm
±5% rdg>100ppm
Carbon Dioxide (CO2) 0~30%** 0~30%** 0~20%* 0~20%*
CO2 resolution / accuracy 0.1% / ±3% 0.1% / ±3% 0.1% / ±2% 0.1% / ±2%
Efficiency** 0~99.9%** 0~99.9%** 0~99.9%** 0~99.9%**
Efficiency resolution/accuracy 0.1% / ±3% 0.1% / ±3% 0.1% / ±3% 0.1% / ±3%
Excess Air** 0~250%** 0~250%** 0~250%** 0~250%**
Excess Air resolution/accuracy 0.1% / ±3% 0.1% / ±3% 0.1% / ±3% 0.1% / ±3%
CO/CO2 ratio** 0~0.999 0~0.999 0~0.999 0~0.999
CO/CO2 resolution/accuracy 0.001 / ± 5% rdg 0.001 / ± 5% rdg 0.001 / ± 5% rdg 0.001 / ± 5% rdg
Nitric Oxide (NO1) - -0~100 ppm - 0~100 ppm
NO1 resolution/accuracy - ±2 ppm<30ppm - ±2 ppm<30ppm
- ±5 ppm<100 ppm - ±5ppm<100 ppm
Pressure (Differential) Range Accuracy
±0.08” wc (±0.2mBar) ±0.002” wc (±0.005mBar)
±0.4” wc (±1mBar) ±0.01” wc (±0.03mBar)
±32” wc (±80mBar) ±3% rdg
Pressure Resolution 0.001” wc < 9.999” wg
0.01” wc >10.00” wg
0.001mBar<24.999mBar
0.01mBar > 25 mBar
* Measured at STP (standard temperature and pressure)
** Calculated value